Release AHU Design v. 4.7.0 (2025-09-25)

 

HIGHLIGHTED NEWS

 

CASA GENIUS R7-H and CASA W5

CASA GENIUS R7-H and CASA W5 is now selectible in AHU Design for the European market.

 

New for GOLD/SLIVER C PX40+, PX50+ and PX60+

Now possible to Select Factory Assembled or Dismountable heat exchanger in AHU-Design

 

 

 

Updated icons in design view on GOLD and SILVER C

To facilitate all choices made on functional parts in AHU design, we have now introduced new detailed icons for fans, filters, and heat exchangers. These icons will  display following:

 

Fan: Size and motor option

Filter: Selected filter class

Hex: Performance and type of coating

 

 

 

Replacing standard supply air bag filters

During the autumn/winter we will replace our standard supply air bag filters ePM1 50% to a better grade, ePM1 60%

The filter now introduced as standard has a better filtration rate (60% instead of 50%) and also a lower pressure drop.

 

The new filter media is green while the previous one is white, thats way it is easy to notice the difference.

 

In AHUD this filter has been available as one of the optional calculations for quite some time, but now we step by step will change over in our deliveries.

To avoid waste the change will be done size by size of the different GOLD/SILVER C units.

Consequently during this period some units will have the old filter and some will have the new better filter.

 

In AHUD we remain on the old filter until all AHU sizes are changed in the factory, since we that way will deliver filters as current standard or better during the transition period.

When the change is completed in the factory AHUD will be updated using the new filters as standard.

 

 

PassivHaus Updates for CASA and GOLD/SILVER C

 

Certified CASA Units Now Available in AHU Design

CASA units with PHI certification are now selectable as PassivHaus certified in AHU-Design.

 

Updated PHI Compliance Check

 

The compliance logic now reflects PHI’s interpretation of the design point when a unit can be guaranteed to meet the performance metrics outlined in its certificate.

 

The following criteria are now validated when “Calculate PassivHaus” is selected:

 

Airflow Range: Must be within the certified range.

External Pressure: Must not exceed certified limits. Formula for determining external pressure of AHU reviewed and updated.

Flow Balance: Supply vs. Exhaust airflow balance is now required (within ±10% tolerance).

Filter Quality: Non-compliant filters with certification requirements are disabled for calculating PassivHaus compliance.

 

IMPORTANT!

Due to review of the compliance criteria above, some AHUs that previously passed the PHI compliance check may now fail due to the stricter validation, most likely due to new Flow Balance criteria.

 

 

 

APPLICATION / GUI / Calculation

 

Improvement: SFPv and temperature Efficiency value is now visible in project list.

 

 

Improvement: Requested calculation results from AHU Design are now available for coils in REVIT and AUTOCAD.

 

 

Improvement: New dropdown list for selecting components in AHU Design.

 

 

Improvement: Modine Pricelist update for Q3 2025

Improvement: Improved DirectCoil property selection.

Bug-fix: Energy calculation support the “Recirculation and electric heater" mode for HC

Bug-fix: Barcode printout update for GLOBAL and ESSENSA.

Bug-fix: Liquid coil printouts

Bug-fix: Names are correct automatically added on multifunctional subcomponents.

Bug-fix: When updating from the MagiCAD plugin, the window now opens directly to the AHU Design unit view instead of taking you to the project list.

 

 

Bug-fix: Issue with importing duct components when reading .mah files in Revit. The problem existed in the MagiCAD plugin, and a new version is now available for download at following url: https://portal.magicad.com/download/ProductSearch?searchStr=Swegon&categoryId=3.

 

Bug-fix: The issue with incorrect icon scaling during export to DXF file has been corrected.

Bug-fix: Upwards duct connection missing on SD units in Sketch and DXF printouts.

Bug-fix: Norwegian language fix

Bug-fix:Added missing icons for ACTR and ACBR products in Sketch prinout

Bug-fix: Performance improvements related to unit ordering 

Bug-fix: Automatic re-routing to order view if a unit is open in AHU Design when the unit is ordered in SBT 

Bug-fix: Fixed issue where unit size in design view sometimes not updating correctly

Bug-fix: Barcode correction for FLEX 20 in outdoor version

Bug-fix: The liquid volume inside the pipes of the coil is now displayed in both the app and in the printout

Bug-fix: Duct component roof is availavble in Design view

Bug-fix: Added text in the Tag, Lines, and Placement fields no longer converts to E notation (e.g, 2E+14).

 

KVÄNUM

 

Improvement: Increased maximum function parts from 5 to seven on GOLD and SILVER C (29503)

Improvement: Intake up to size 40 is now configurable, not a special selection (37022)

Improvement: Warnings for air temperature and humidity out of range (36601)

Improvement: Measurement of half PX exchanger in top view (36083)

Improvement: Max work pressure changed when Epsilon Sky is used as a heatpump on DX coils (36875)

Improvement: Logic for article TBLZ-2-53 (34303)

Improvement: Updated wiring diagram for pressure sensor on GOLD SD (36016)

Improvement: Smart Link DX for all hex types (36901)

Bug-fix: Duct reverse section crashed for sizes over PX 40 (36027)

Bug-fix: Visual graphics for TCRS on GOLD/SILVER PX size 8 End sections Exhaust up(36436)

Bug-fix: Fan diagram for PX size 11 and 12 with duct reverse section (36070)

Bug-fix: Automatic transformer was not added correct on PX size 70 and 80 when main voltage to building was 3x230V (36426)

Bug-fix: Filter section had wrong amount of support feets for GOLD/SILVER SD CX (36479)

Bug-fix: Corrected order codes for ABC-BANS (35915)

Bug-fix: Update logic for TCBC (36722)

Bug-fix: Wiring diagram update for digital control of coils (35779)

Bug-fix: Corrected logic for TCKC/TBKC silver units (36850)

Bug-fix: Wiring diagram corrected for application with two smoke detectors (36969)

Bug-fix: Corrected description for symbol BT25 in flowchart (37004)

Bug-fix: Passivhaus calculation not valid when one or both sides are TOP-connections (37165)

Bug-fix: TCGA could be placed between fan and filter on GOLD/SILVER SD (37201)

Bug-fix: Corrected side view on GOLD HC size 80 (37202)

Bug-fix: Corrected the calculation of number of plates for TBTB size RX 80+

Bug-fix: Updated Nom. pipe connection, coil on size 30 TCLA capacity variant 2 (37254)

 

GEMBLOUX

 

Improvement: INSIDE Connect enabled under controlsystem (36837)

Improvement: Added SAT MQTT under controlsystem (35879)

Improvement: Protective cover on rotary actuators for dampers (36836)

Improvement: Transport package for Global LP and Esensa range (35880)

Bug-fix: External dimension for connection component on Esensa PX TOP size 13 (36646)

Changed: Global size 14 is now size 11 (36835)

Changed: Global LP size 12 and 13 is phased out (36834)

 

NORTH AMERICA

 

Improvement: All units are now available in transport package (30226)

Improvement: MERV 8 filter logic (35933)

Improvement: Added article HGRH CTRL under unit accessories (34949)

Improvement: Increased positions where ACTR can be placed (35948)

Improvement: Flowchart: ABSA factory assembled (35897)

Improvement: M3 configurations for DX coils (36402)

Improvement: Reviewed capacity alternatives on ACLE (36485, 37006)

Improvement: Increased number of brazings for ACKC (36730)

Bug-fix: Corrected symbol names in flowchart for coils (35899)

Bug-fix: Reviewed cased components weight (27147)

Bug-fix: Flowchart of smoke detectors in supply (35876)

Bug-fix: Corrected ordering codes and configurations for ABSA mounted on unit (36000, 36929)

Bug-fix: Corrected upward connections on several units (36401)

Bug-fix: Electrical data for size 8 on electrical coil ACLE (35900)

Bug-fix: Voltage configurations is harmonized between ACTR and the unit (37029)

Bug-fix: Config mismatch of ACLK with two DX coils (37030)

 

KAARINA

 

Improvement: Electrical connections in technical printout (35429)

 

Improvement: Functional description printout for CASA products is now available un AHU Design. (34650)