PACIFIC
- Low-profile chilled beam with integrated induced air opening in the bottom and 2-way horizontal discharge
- Provides ventilation, cooling, and/or heating
- Designed to be installed in suspended ceilings.
- Adjustable discharge slots
- Hinged faceplate design section for easy accessibility and service
- Simple adjustment on site
- Standard color White RAL 9003
- Other colors upon request
PACIFIC is a low-profile 2-way distribution active chilled beam for constant air volume ventilating, cooling, and/or heating.
The casing is manufactured in galvanized sheet steel (zinc plated) The face plate is in prepainted sheet steel and aluminium RAL 9003, Coil in copper and aluminium.
Standard colour:
- RAL 9003 White (Signal white), gloss ratio 30 ± 6%
Alternative standard colours:
- RAL 7037 Grey (Dusty gray), gloss ratio 30-40%)
- RAL 9010 White (Pure white), gloss ratio 30-40%)
- RAL 9005 Black (Jet black), gloss ratio 30-40%)
- RAL 9006 Silver (White aluminium), gloss ratio 70-80%)
- RAL 9007 Grey (Grey aluminium), gloss ratio 70-80%)
- Other colors available on request
The PACIFIC is supplied with four mounting brackets and self-tapping screws packaged separately and supplied with each unit. The pre-punched holes in each mounting bracket simplify the fastening work.
The mounting brackets are designed enabling them to be turned in any optional direction depending to suit type of suspension system selected. Turned inward, the mounting brackets offer simple installation by means of mounting strips. Turned outward, the mounting brackets work at their best for suspending the beams by means of size M8 threaded rods.
Mounting strips and threaded rods are not supplied with the unit. If assembly fittings are required, these can be ordered separately.
Primary airflow: | Typical 116 CFM (up to 200 CFM) |
Pressure range: | Typical 0.5 inWG (up to 0.75 inWG) |
Cooling capacity: | Up to 8872 Btuh |
Heating capacity: Water: | Up to 10, 236 Btuh |
  | |
Lengths: Min. | 47 in / max. 120 in* |
Widths: | Min. 23.4 in / max. 26.26 in* |
Heights: | 6.4 in - with Ø4 in air connection |
7.4 in - with Ø5 in air connection | |
10.9 in - with Ø6 in air connection | |
*Lengths and widths are matched to suit different types of false ceilings. |
Document | Article | Document type | Download |
---|---|---|---|
Chilled Beam Guide Specification (docx 55.05kB) | ADRIATIC, PARAGON, PARASOL Zenith, PACIFIC, PARASOL | Engineering | |
Operation and maintenance (pdf 40.14kB) | FRB; PACIFIC, ADRIATIC, ADRIATIC AWC. WISE Adriatic | IOM Manual | |
Compliance declaration (CE), variant X (pdf 93.34kB) | PACIFIC | Quality | |
Building product declaration (pdf 50.53kB) | PACIFIC | Quality | |
Integrated chilled beam (pdf 3.1MB) | PACIFIC | Technical catalogue | |
Installaton-Commissioning-Maintenance (NA) (pdf 2.4MB) | PACIFIC | IOM Manual |