PACIFIC HC
- High-capacity chilled beam with integrated induced air opening in the bottom and 2-way horizontal discharge
- Provides ventilation, cooling, and/or heating
- Designed to be installed in suspended ceilings.
- Adjustable discharge slots
- Hinged faceplate design section for easy accessibility and service
- Simple adjustment on site
- Standard color White RAL 9003
- Other colors upon request
PACIFIC HC is a high-capacity 2-way distribution active chilled beam for constant air volume ventilating, cooling, and/or heating.
The casing is manufactured in galvanized sheet steel (zinc plated) The face plate is in prepainted sheet steel and aluminium RAL 9003, Coil in copper and aluminium.
Standard colour:
- RAL 9003 White (Signal white), gloss ratio 30 ± 6%
Alternative standard colours:
- RAL 7037 Grey (Dusty gray), gloss ratio 30-40%)
- RAL 9010 White (Pure white), gloss ratio 30-40%)
- RAL 9005 Black (Jet black), gloss ratio 30-40%)
- RAL 9006 Silver (White aluminium), gloss ratio 70-80%)
- RAL 9007 Grey (Grey aluminium), gloss ratio 70-80%)
- Other colours available on request
Installation
The PACIFIC HC is supplied with four mounting brackets and self-tapping screws packaged separately and supplied with each unit. The mounting brackets can be located at any position along the entire long side of the unit for maximum adjustability. The pre-punched holes in each mounting bracket simplify the fastening work. The mounting brackets are designed to be turned in any optional direction depending on the type of suspension system selected. Turned inward, the mounting brackets offer simple installation by means of mounting strips. Turned outward, the mounting brackets work at their best for suspending the beams by means of threaded rods. Threaded rods must be ordered separately and are available in a variety of lengths. Mounting strips are by others.
Connection dimensions
Cooling (water): 1/2" NPT threaded Heating (water): 1/2" NPT threaded Air: Insertion joint, 125, 150 or 200 in nominal diameter
| Primary airflow: | Typical 25-250 CFM (up to 330CFM) |
| Pressure range: | Typical 0,5 inWG (up to 0,75 inWG |
| Cooling capacity: | Up to 12 000 Btuh |
| Heating capacity: Water: | Up to 15 000 Btuh |
|   | |
| Length: | Min. 47 in/ Max 120 in* |
| Widths: | Min. 23,4 in / Max 23,7 in* |
| Heights: | 10,7 in |
| Air connections: | Ø 5 in |
| Ø 6 in | |
| Ø 8 in | |
| *Lengths and widths are matched to suit different types of false ceilings. | |
| Document | Article | Document type | Download |
|---|---|---|---|
| Installation – Commissioning – Maintenance (NA) (pdf 1.96MB) | PACIFIC HC | IOM Manual | |
| integrated chilled beam (pdf 1.37MB) | PACIFIC HC | Technical catalogue | |
| PACIFIC family (pdf 1.6MB) | PACIFIC, REACT Pacific | Brochure |