Product view, Air connection=Side 4, L=1200
Inverted product view, Air connection=Side 4, L=1200
PARASOL Zenith with design kit and coanda frame for suspended installation

Product in context
Suspended solution with PARASOL Zenith, design kit and coanda frame in green colour. Photo, Felix Gerlach
Suspended solution with PARASOL Zenith, design kit and coanda frame in pink colour. Photo, Felix Gerlach
REACT Parasol Zenith
Chilled beam with integrated variable flow regulation
- Chilled beam with induced air opening in the bottom and 4-way horizontal discharge.
- Provides ventilation, cooling, and/or heating
- Designed to be installed in ceilings.
- Internal damper with 24-volt damper actuator for integration with room controls or BMS.
- The product is equipped with an actuator for flow adjustment, terminal block and air connection for flow measurement
- Simple commissioning because the flow measurement is performed directly in the air connection
- Pressure-independent flow regulation
- Can easily be integrated by a control equipment supplier via Modbus communication
- Large span between the lowest and highest air flow
- Few variants for easier sizing and variable air flow control
- Optimised for low energy consumption
- Manages high air flow at low driving pressure
- Easy installation on account of low weight, compact dimensions and optional air connections on short or long sides
- Hygiene design as an option for hospital applications
- Standard colour White RAL 9003
- Other colors upon request
Variant | Supply air | Performance | |||
Size ft. | Air connection in. | IN WG* | CFM | Total cooling capacity (BTUH)** | Sound level (dB(A)) |
2 | 5 | 0.3 | 42 | 1683 | 26 |
2 | 5 | 0.3 | 53 | 1925 | 28 |
2 | 5 | 0.3 | 64 | 2154 | 30 |
2 | 6 | 0.3 | 53 | 1932 | 27 |
2 | 6 | 0.3 | 74 | 2379 | 30 |
2 | 6 | 0.3 | 95 | 2761 | 33 |
4 | 5 | 0.3 | 53 | 3010 | 26 |
4 | 5 | 0.3 | 74 | 3676 | 28 |
4 | 5 | 0.3 | 95 | 4157 | 30 |
4 | 6 | 0.3 | 64 | 3072 | 23 |
4 | 6 | 0.3 | 127 | 4693 | 28 |
4 | 6 | 0.3 | 170 | 5430 | 34 |
6 | 8 | 0.3 | 127 | 5427 | 30 |
6 | 8 | 0.3 | 170 | 6451 | 33 |
6 | 8 | 0.3 | 212 | 7287 | 35 |
* Total pressure duct (In wg) | |||||
** Air: ΔTl=12.6ºF / Water: ΔTmk=15.3ºF, twater=57.2/62.6ºF |
Filter
Comprehensive detailed product information for the best selection and integration in project design
Installation, Operating, Maintenance and Safety information
Our products and services presented in an easy-to-access manner
Declarations and certificates etc
Wiring diagrams and hydraulic schemes etc
Document | Article | Document type | Date | Download |
---|---|---|---|---|
BACnet settings - Belimo (pdf 79.34kB) | REACT Parasol Zenith | IOM Manual | 6/4/2025 | |
Comfort module with integrated variable flow regulation (en) (pdf 6.05MB) | REACT Parasol Zenith e | Technical catalogue | 5/26/2025 | |
Chilled beam with integrated variable flow regulation (NA) (pdf 5.22MB) | REACT Parasol Zenith | Technical catalogue | 6/26/2025 | |
Design kit and coanda frame (pdf 3.23MB) | PARASOL Z DK, PARASOL Z CF | Brochure | 6/27/2025 | |
Declaration of conformity (CE) (pdf 102.79kB) | REACT Parasol Zenith e | Quality | 1/12/2025 | |
Modbus settings – Gruner (pdf 186.19kB) | REACT ALS GMB, REACT M GMB, REACT P GMB, REACT PX GMB, REACT PX-SR GMB, REACT V GMB, REACT V-SR GMB | IOM Manual | 9/30/2024 | |
Modbus settings – Belimo (pdf 141.65kB) | REACT V BMB, REACT Parasol Zenith | IOM Manual | 10/3/2023 | |
Description of functions & wiring diagrams – Gruner (pdf 3.87MB) | REACT ALS GMB, REACT M GMB, REACT P GMB, REACT PX GMB, REACT PX-SR GMB, REACT V GMB, REACT V-SR GMB | IOM Manual | 9/30/2024 | |
Installation - Commissioning - Maintenance (NA) (pdf 7.19MB) | REACT Parasol Zenith e | IOM Manual | 6/26/2025 | |
Installation, commissioning, maintenance (en) (pdf 8.08MB) | REACT Parasol Zenith e | IOM Manual | 1/12/2025 |