Release AHU Design v. 4.3.14 (2025-01-30)
APPLICATION / GUI / Calculation
- Improvement: Add circulation pump effect for CX / SDCX units
- Improvement: New error message for DirectCoil when no configuration received from supplier
- Improvement: Show energy report graphs for alternative operating setups
- Improvement: Allow energy efficiency values to contain Infinity and Not a Number without crashing
- Bug-fix: Country names for United Kingdom and Iceland corrected
- Bug-fix: Amount is not shown correctly in SBT for certain combination coil accessories (NA)
- Bug-fix: Calculation not possible for FLEX
- Bug-fix: Print fix for Key Performance Data – GLOBAL SD
- New technical version 41
KVÄNUM
- Change: The option, direct deliver is removed on Aircoil duct coils. All Aircoils is deliverd from Kvänum factory.
- Improvement: Support to avoid incorrect setup in X-zone (27230)
- Improvement: Configuration of TBKC in X-zone and corresponding wiring diagrams (31758)
- Improvement: Technical printout for special coils (27795)
- Improvement: Wiring of combi coils (TCKA) (30086)
- Improvement: Graphics for silencer. Directions is now graphically corrected (31050)
- Improvement: INSIDE Connect logic and articles/texts (31923)
- Improvement: Given names of zones are used in documentation (17551)
Additionally, the clarfication has been made to Xzone configuration.
- Improvement: Possibility to order ozone resistant vibration absorbers on fans (31945)
- Bug-fix: When drip tray is selected on inspection and empty part (TCIA/TCGA), drain trap is automatically added (31953)
- Bug-fix: M5 filter for direction up (31348)
- Bug-fix: Smart Link DX harmonization (31420)
- Bug-fix: Heat-pump set up for SILVER-units (31423)
- Bug-fix: Disable incorrect duct connection option for TBKA (31706)
- Bug-fix: Corrected transformer in Norway for PX 50+ and 60 + (32081)
- Bug-fix: Protection against incorrect toggling between plus units and standard units (31440)
GEMBLOUX
- Improvement: Adapted order configuration for production in Gembloux (30883)
- Improvement: Updated logic and article structure for output relays (30750)
- Improvement: Possibility to select externally supplied hydraulic preheater (31808)
- Bug-fix: Renamed temperature sensor of IBA to T7. (32399)
NORTH AMERICA
- Improvement: Revised electrical data for electrical heater ACLE (31275)
- Bug-fix: Brazing quantity for order system (31665)
RESIDENTIAL (KAARINA)
- French language (31737)
- Updated several Swedish texts (32384)